NORMAL SERUM CLINICAL CHEMISTRY VALUES FOR MEASURE OF IRON STATUS
IRON MEASURE NORMAL RANGE
BLOOD
Haemoglobin (Hb)
Female 117 - 153 g/L
Male 134 - 170 g/L
year 1-11 110 - 155 g/L
month 6 - 12 90 - 140 g/L
Erythrocytes (Er or RBC)
year 2 - 11 3.9 - 5.3 x 10 12/L
Female 3.9 - 5.3 x 10 12/L
Male 4.3 - 5.7 x 10 12/L
Erythrocyte Volume Fraction (EVF, Hct [PCV]) 1
year 6 - 11 0.35 - 0.45
Female 0.35 - 0.46
Male 0.40 - 0.50
Mean Cell Volume (MCV)
month 6 - 72 70 - 87 fL
year 6 - 11 76 - 95 fL
year 12 - 17 78 - 98 fL
Adults 82 - 98 fL
PLASMA / SERUM
Iron2
Adults 9 - 34 µmol/L
Children lower values
Transferrin (TF)
Adults 2.2 - 3.9 g/L3
Transferrin saturation (TfS) 4
Female 18 - 49 y 10 - 50 %
Female over 49 y 15 - 50 %
Male over 18 y 15 - 57 %
Ferritin (Ft)5
Female 10 - 167 µg/L
Male 29 - 383 µg/L
Transferrin receptor (sTfR)5
0.8 - 1.8 mg/L
1 Calculated automatically: EVF (Hct
2 Day variation
3 Children, pregnant and contraception pill users have higher values.
4 <15 % probable iron deficiency. Possible haemochromatosis: >50 % in females and >60 % in males
5 Values depend on the specific assay used. Possible haemochromatosis: Ft >200µg/L in females and >300 µg/L in males
Data from:
Laboratoriehåndbok for Avdeling for medisinsk biokjemi
(17.4.2012)